Executive boardroom with a long conference table and chairs

Deployment guide

Securing boardrooms and office spaces

A room's protection is only as strong as the routine around it. Sweeps are skipped, units omitted, and alerts ignored because no one documented which transmitters should be present. This guide covers deployment tasks and the recurring procedures that maintain credibility.

Four Elements of a Working Program

Fixed sweep route

Same path, same heights, and identical gain settings on every visit. Results are comparable only if the method remains consistent across technicians.

Approved Device List

Every Wi-Fi access point, wireless microphone, DECT handset, and panic button is recorded with its frequency—so an unknown alert means something.

Switch by session

Enable shielding before room use; disable when empty. Include operator name and timestamp. Permanent transmission invites scrutiny.

Found Device Procedure

Photograph only. Do not touch or access. Improper handling compromises the evidence required for investigation.

Start with a baseline, not equipment

Before the initial sweep, walk the floor with the facilities team and log every transmitter that belongs there. Include wireless access points and their channels, DECT base stations, wireless microphones and receivers, building repeaters, door access readers, panic buttons, and wireless presentation dongles in each room. Record the frequencies, not just the device names.

This list serves two purposes: it transforms subsequent alerts into comparisons instead of guesses, and it prevents the most common pitfall for new programs—the first week of unexplainable constant alerts that leads to the detector being abandoned in a drawer.

Record a quiet baseline in each room with normal equipment running. Months later, any changes will be visible in the log—even if the technician is new.

Room types and standard configurations

Not every room requires the same treatment. Tiering keeps the program affordable and justifies the sweep frequency. 30 MHz–3 GHz handheld detector covers sweep work across all tiers, the 10-channel desktop unit provides room-level protection, and the Handheld Anti-Tracking Device covers meetings held outside a fixed room. The full detection range is under signal detectors.

Room typeSweep frequencyDetectionProtectionWatch out
Boardroom, 20–40 seatsWeekly, and before each sensitive sessionHandheld detector 30 MHz–3 GHz10-channel desktop unit or room-level shieldingInspect the underside of tables, ceiling voids, and wall plates with every sweep.
Executive officeWeekly, following any visitor or maintenance visitHandheld detectorHandheld unit for ad-hoc meetingsDesk equipment, gift items, and furniture deliveries are typically handled by standard carriers.
Huddle room, 4–8 seatsMonthlyHandheld detectorShared desktop unit on a cartShared rooms drift out of procedure fastest; label the unit and checklist.
Secure communications roomBefore each session and after every contractor visitDetector plus physical inspectionDedicated room with scheduled switching and access controlLog entry, sweep result, and activation time as a single record set

Sweep intervals serve as a baseline for facilities with defined sensitivity policies. They must align with the organization's specific security requirements, not generic schedules.

How to perform a sweep

  1. 01

    Confirm the room is empty and that phones, laptops, and presentation dongles are removed or powered off in a tray.

  2. 02

    Set and record the detector gain. Changing this setting during a future visit will make the logs incomparable.

  3. 03

    Walk the perimeter at desk height, then chest height, and near the ceiling line, keeping the antenna close to surfaces rather than in the middle of the room.

  4. 04

    Sweep the table edges and underside, then the ceiling void and light fixtures if accessible.

  5. 05

    Check wall plates, floor boxes, power strips, smoke detectors, and any equipment added since the last visit.

  6. 06

    Note every alert's frequency, strength, and position, and verify it against the approved device list before exiting the room.

  7. 07

    Sign and submit the sheet with the room record; escalate any unresolved issues instead of deferring them to the next visit.

A sweep detects devices that are actively transmitting. Locally recording devices that transmit later will not be detected, which is why the physical walkthrough in steps five and six is required—not optional. This is also why rooms should be swept after cleaning crews, contractors, and furniture deliveries arrive, not just before important meetings.

Session procedure

Session protection is enabled and remains active only while the session is in progress. The operator verifies that the room contains no unapproved devices, activates the room unit, confirms the indicator light, and logs the start time along with the unit ID. After the meeting, the same operator deactivates the unit and records the end time.

When using a networked unit, the schedule covers common cases while the operator manages exceptions. In either scenario, staff radios, building intercoms, and any active medical devices must be verified as functional outside the affected frequency bands during initial sessions—do not assume they are working.

Rooms that host visitors require an additional step: a brief search after departure, before the room returns to normal use. Gift items, chargers, and promotional electronics are common concealment points.

Water Leakage and Adjacent Rooms

Measure at the doorway, in the hallway, and in the adjacent room while the unit is active. Signal spill into neighboring offices can trigger complaints and may create compliance issues in some jurisdictions. The solution is typically to lower the power setting or position a smaller unit inside the room instead of using a larger one in the hallway.

For rooms with large glass partitions, measure from the outside of the glass as well. Glass does not block signals; a meeting that appears private may still be visible from a shared corridor.

Six things that undermine the program

No approved devices

Every sweep triggers alerts, staff lose trust in the detector, and the routine quietly fails.

Sweeps performed only before major meetings

A device installed in week 1 is found in week 12. Frequency matters more than intensity.

Unit permanently disabled

Building systems and staff radios are failing, neighbors are complaining, and the transmission window is no longer viable.

One shared unit for multiple rooms

Shared equipment often ends up in the wrong room. Either tier your rooms or accept that some will remain uncovered.

No record of who did what

Without names and timestamps, an audit cannot distinguish a protected session from an unprotected one.

Detector only, no physical pass

Local storage recorders do not transmit. Physical inspection is the layer that detects them.

Legal boundaries

Detection and shielding are distinct activities governed by different rules. Sweeping a room for unauthorized transmitters is generally permitted on premises you control; intercepting or recording communications is not, and no product changes that fact. Where an organization follows a specific policy, the sweep log should adhere to that policy rather than a supplier template.

Shielding transmissions require authorization and a designated frequency assignment in most jurisdictions, and should be used only for the covered sessions and rooms. Any devices found in a room must be turned over to the security team responsible for the incident, not to the person who discovered them.

Room-level shielding options are described in Signal shielding for corporate and government facilities, and cable and connector loss for in-room installations are covered in the RF cable and connector guide.

Frequently asked questions

Sweep and Detect

Can a handheld detector locate a hidden transmitter in a conference room?

It detects active transmitters during sweeps, covering most live devices but missing local recorders that transmit later. That is why detector sweeps must be paired with physical inspections of tables, ceiling voids, and wall plates. A detector is a fast filter—not a substitute for looking.

How should a sweep be performed?

Follow a consistent route to ensure comparable results across visits: begin at the door, scan the perimeter at three heights, then check the table line, and finally inspect the ceiling void if accessible. Keep the antenna close to surfaces rather than in the center of the room, record the gain setting, and document any unidentified sources before proceeding.

False alarms and approved devices

Why does the detector trigger an alert in a normal meeting room?

Normal rooms contain many transmitters: Wi-Fi access points, wireless microphones, DECT handsets, building repeaters, panic buttons, wireless presentation dongles, and door access readers. Inventory every approved device and its frequency before the first sweep so alerts pinpoint only the sources not on your list.

Should shielding remain in place permanently?

No. Room shielding is activated only for the session and deactivated afterward to ensure staff radios, medical devices, and building systems continue operating normally outside the meeting. Leaving a room unit running also makes the space appear unusual to visitors and raises ongoing compliance concerns about unauthorized transmissions.

Room protection

Is a jammer sufficient to secure a boardroom?

It removes the phone and Wi-Fi path—the most common source of leaks—but offers no protection against recorders with local storage, cameras, or devices already compromised in the room. Effective deployments rely on three layers: shielding, detection, and a physical routine.

How do you prevent leaks into the corridor and adjacent room?

Keep the unit inside the protected room, not in the corridor. Set power to the room volume, not the maximum available. During commissioning, measure at the door threshold and in the adjacent room. A room that appears enclosed from the corridor may look fine on a floor plan but fail at the far wall.

Procedures and records

What should the meeting-day checklist include?

Per-room sweep results, approved device exceptions, shielding activation time with unit ID and operator, any alerts raised and their resolution, and deactivation time. One sheet per session, filed with the room record, satisfies both internal audits and external inquiries.

What should we do if a device is detected?

Do not power off, open, or move the device beyond what is necessary. Photograph it in its current location, record the time and room, restrict access, and hand it over to the security team responsible for the incident. Improper handling can destroy the evidence trail needed for an investigation and may trigger a remote alert.

Part of the BCSK engineering library: amplifier thermal design, cable loss, antenna coverage, deployment planning, and field procedures.

All technical guides

Setting up room protection?

Tell us the number of rooms, approximate seating capacity, and whether a fixed or handheld cover fits your schedule. We'll provide a tiering plan with detectors and room units.

Request a room layout

Provided to authorized organizations only. Verify local permissions and operating limits before deployment.

Contact via WhatsApp