Coaxial cable assemblies and RF connectors laid out on a workbench

Technical guide

What actually reaches the antenna

A 20 W module and a 20 W antenna do not make a 20 W system. Between them sit several metres of cable, two connectors and often an adapter or a surge arrestor, and each of those subtracts from the number on the module label. This is the part of a build that is easiest to get wrong and cheapest to get right.

Why 3 dB is the number to remember

Loss is measured in decibels, and 3 dB is a factor of two in power. A 20 W module behind 3 dB of path loss delivers 10 W to the antenna; 6 dB leaves 5 W. That is not a rounding error, it is half the system, and it usually arrives through a combination of long thin cable, an adapter stack and a joint that was never properly made.

Coverage does not fall by half when power does, because field strength drops with distance and depends on the antenna pattern. What changes is the margin at the edge: the far corner of a hall, the end of a convoy route, the outer boundary of a protected site. Loss eats the margin first, and the margin is what the deployment was bought for.

Build the budget at the highest frequency the system uses. Every cable in this article is worse at 5.8 GHz than at 1.5 GHz, and a multi-band module generates all of it at once.

Cable families compared

The figures below are typical attenuation in dB per metre for 50 ohm assemblies, at the three bands most counter-UAS and jammer builds use. Treat them as planning values and confirm against the supplier datasheet for the exact assembly you buy.

Cable familyO.D. (mm)dB/m @ 1.5 GHzdB/m @ 2.4 GHzdB/m @ 5.8 GHzWhere it belongs
RG316 / RG58 jumper2.5 / 50.9 – 1.11.2 – 1.41.9 – 2.3Short test leads and cabinet jumpers, under 1 m
50-5-3 semi-flexible5.30.28 – 0.350.36 – 0.450.55 – 0.70Fixed indoor runs from module to antenna, 3–15 m
50-7 / LMR400 class10.30.18 – 0.220.23 – 0.280.35 – 0.45Long fixed runs, mast and rooftop feeds
50-9 super flexible9.00.20 – 0.250.26 – 0.310.38 – 0.48Runs that need a tight bend radius, vehicle installs

Two rules follow from the table. Thin cable belongs inside the enclosure, where it is short. Anything leaving the cabinet is 5 mm or larger. A 10 m run on RG316 looks tidy and costs several decibels at 5.8 GHz, which is exactly the band that decides whether the install works.

Connectors and adapters

Connector loss is small per joint and easy to ignore per joint, which is why it adds up. Count every interface between the amplifier output and the radiating element: the module port, each cable end, each adapter, the surge arrestor and the antenna input.

InterfaceFrequency rangeLoss per pair (dB)Practical note
SMA male / femaleDC – 18 GHz0.05 – 0.15Fine thread, easy to under-torque; not a weather connector
N male / femaleDC – 11 GHz0.05 – 0.12Preferred outdoors; seal the joint, not the thread only
Adapter chainsPer interface0.1 – 0.3 per pairEach pair adds loss and a reflection; buy the right cable end instead
Crimp vs solderSame interfaceComparableCrimp needs the matching die; a wrong die is worse than either

A crimp is only as good as the die it was made with. The most common connector fault we see in returned assemblies is a crimp formed with the wrong die: the ferrule looks closed, the pull test passes by hand, and the joint still adds a fraction of a decibel and a reflection that shows up as a hot spot on a sweep. Solder joints fail differently, with a brittle centre pin after repeated mating.

A worked budget: 20 W through 10 metres

Take a 1.5 GHz module rated 20 W, a 10 m indoor run and a rooftop antenna. Using the typical figures above:

  1. 01

    Module output 20 W equals 43 dBm.

  2. 02

    10 m of 50-5-3 at about 0.3 dB per metre: 3.0 dB.

  3. 03

    Two connector pairs at 0.1 dB each: 0.2 dB, plus one adapter pair at 0.15 dB.

  4. 04

    Surge arrestor, where fitted: 0.2 dB.

  5. 05

    Total path loss: about 3.55 dB, so roughly 8.8 W reaches the antenna input.

Nothing in that chain is faulty. It is simply what a 10 m run costs at the band, and it explains why an installer who replaces a 10 m run with a 20 m run reports a coverage problem rather than a cable problem.

Run the same budget at 5.8 GHz and the cable term roughly doubles. On a multi-band system, size the cable for 5.8 GHz even if the 1.5 GHz channel is the one being demonstrated.

Six faults that cost more than the cable

Under-torqued SMA

A finger-tight SMA adds loss and drifts with vibration. Use the specified torque and a proper wrench on the hex, not pliers on the knurl.

Wrong crimp die

The ferrule closes but the joint is not gas-tight. It passes on the bench and corrodes in the field.

Bend radius ignored

A tight loop changes impedance locally and can crack the dielectric. Respect the manufacturer radius, especially at the connector transition.

Water in an N joint

Tape wrapped over a wet connector seals the water in. Dry, seal with self-amalgamating tape, then a weatherproof layer, and leave a drip loop.

75 ohm parts in a 50 ohm chain

Television cable and F connectors appear in installs more often than anyone admits. The mismatch raises loss and can stress the amplifier.

Adapter stacks

Three adapters to avoid making one correct assembly is a false economy: each pair costs loss, reflection and a joint that can loosen.

Measure before you install

Sweep every assembly on a vector network analyser before it goes up. Log insertion loss across the whole operating band, not at one spot frequency, and record return loss at the same time. Label the cable and file the sweep against the label: when a channel later looks weak, you want to know whether the cable was ever good.

Re-measure after the first weather cycle on outdoor runs. A joint that was dry at installation and is wet a month later shows up as an increase in loss long before anyone sees water.

When to move the amplifier instead

Above roughly 15 m, or whenever the budget exceeds 3 dB, the cheaper answer is often to put the module at the antenna and run DC or mains to it. A short jumper plus a weather enclosure usually costs less than the next cable size up, and it removes the loss permanently rather than reducing it.

If the module must stay in the cabinet, consider a remote-head arrangement: keep the amplifier outdoors with the antenna and send only control and power down the mast. Both approaches need the thermal plan checked, because a module in a sealed enclosure derates differently from one in a rack.

Lower loss means higher radiated power at the antenna. Re-check the authorised output and any site-specific limit after changing cable or antenna, rather than assuming the previous approval still describes the installation.

The full accessory range is under drone jammer accessories and jammer accessories; band planning for the same builds is covered in the module integration guide.

Frequently asked questions

Cable selection

Is thicker cable always better?

Better for loss, not always for the installation. A 10 mm cable cannot make a 30 mm bend radius and will not survive a hinged cabinet door. Choose the thinnest cable that keeps total loss where you need it, and use a thin jumper only for the last short section inside the enclosure.

How much loss is acceptable between module and antenna?

There is no universal number, but most integrations look for under 1 dB inside a cabinet and under 3 dB for an outdoor run, calculated at the highest operating frequency rather than the centre of the band. If the run needs more than 3 dB, moving the amplifier closer to the antenna is usually cheaper than buying heavier cable.

Loss in practice

Does 3 dB of loss really halve the power?

Yes for power: 3 dB is a factor of two, so 20 W at the module becomes about 10 W at the antenna. Coverage does not halve, because the field falls off with distance and the relationship depends on antenna pattern and environment, but the margin at the far edge of the protected area shrinks quickly.

Why do cables get worse at 5.8 GHz?

Attenuation rises roughly with the square root of frequency for a given dielectric, so a cable that runs 0.3 dB per metre at 1.5 GHz will be close to 0.6 dB per metre at 5.8 GHz. A multi-band system has to be budgeted at the highest band it uses, not the lowest.

Connectors

SMA or N for a drone jammer build?

N for anything that leaves the enclosure or is handled outdoors, and for cable diameters above about 5 mm. SMA is fine for module ports, internal jumpers and bench testing. If the module port is SMA and the antenna is N, use a single cable assembly with the two ends made correctly instead of stacking adapters.

Do adapters really cost that much?

Each mating pair is typically 0.05 to 0.15 dB, and a chain of three adapters plus two cable ends can quietly add close to 1 dB. Adapters also add reflections and a mechanical joint that can work loose. Count every interface in the budget, not just the cable.

Measurement and installation

How should cable assemblies be checked before installation?

Sweep insertion loss across the full band on a vector network analyser, log the value against the cable label, and check return loss at the same time. A cable that passes at 1.5 GHz can fail at 5.8 GHz, so sweep the whole range the system uses. Keep the record with the installation sheet.

What causes loss to grow after a few months outdoors?

Water in the connector, corroded centre pins and a cable crushed against a sharp edge. Seal N joints with self-amalgamating tape and a back-to-back layer, leave a drip loop before the connector, and support the cable every 50 cm so the weight is not carried by the joint.

Part of the BCSK engineering library: amplifier thermal design, cable loss, antenna coverage, deployment planning and field procedure. For cable choice, termination and sealing, see feeder length and connector craft.

All technical guides

Sizing cable for a build?

Send the band, module output and the distance between cabinet and antenna. We will return a loss budget for two or three cable options and the connector ends each one needs.

Request a loss budget

Supplied to authorised programmes only. Confirm local permissions and output limits before deployment.

Contact via WhatsApp